“Chigo Chiller ac supplier in Bangladesh” CLS-F30HW/S
Chigo is the global brand in the world. Chigo air conditioner and Home Appliance export in 200 country world wide. Now, You will get all kinds of chigo Air conditioner product and Home Aplliance from us. Chigo has global reputation for reputed product. Chigo air conditioner product respone and customer review is very High.
You will get your commerial air conditioner from us because now we selling chigo commercial air conditioner. It has huge demand in commercially.Chigo Vrf, Chigo chiller, Chigo Duct split, Multi Split is Now avilable in here with best price and service.
Some Special Feature:
- AIR COOLED MODULAR CHILLER
- Power Consumption High.
- Service manual very easy.
- CLS-F30HW/S
- 30 kW
- R410a
Type of Unit | AIR COOLED MODULAR CHILLER | ||
Model | Number | CLS-F30HW/SR1 | |
Capacity | Cooling | kW | 30 |
Btu/h | 8.5 | ||
Capacity | Heating | kW | 32 |
Power Supply | V/Ph/Hz | 380/3/50 | |
Power Supply | Manual switch | 100 | 150 |
Fuse | 50 | 100 | |
Compressor | Type | Scroll | |
Brand | Copeland | ||
Model | ZP144KCE-TFD-522 | ||
Quantity | 1 | ||
Power Input | Cooling | kW | 11.1 |
Cooling rated current | A | 19 | |
Heating | kW | 10.8 | |
Heating rated current | A | 18 | |
Max. Input consumption | kW | 16 | |
Max. Current | A | 29 | |
Refrigerant | Type | R410a | |
Refrigerant control | EXV+Capillary throttle | ||
Weight | Kg | 7.0 | |
Condenser (Air side) | Air side heat exchange | Finned coil pipe type | |
Fan motor | Qty | 1 | |
Air flow volume | 10³/m³/h | 12 | |
Fan motor model | YDK550-6S01 | ||
Fan motor rated current | A | 4.2 | |
Fan motor input | kW | 0.911 | |
Evaporator (Water side) | Water side heat-exchanger | Shell and tube | |
Water resistance loss | kPa | 30 | |
Water inlet/outlet pipe line inside normal diameter | mm | DN40 | |
Water flow volume | m³/h | 5.16 | |
Max. Pressure | MPa | 1.1/2.75 | |
Water Pipe connection type | Flange connection | ||
Diamension | Nett (W x H x D) | mm | 1160 x 2090 x 900 |
Packing size (W x H x D) | mm | 1240 x 2250 x 950 | |
Weight | Nett weight | Kg | 320 |
Gross weight | Kg | 330 | |
Connection wiring | Power wiring | mm | 16mm 2x3+10mm 2x2 |
Signal wiring | mm | (0.5~1) mm 2x2 | |
Control Type | Wired controller | ||
Safety protection device | Power supply protection (lack of phase, sequence, frequence, voltage). | ||
Chiller water pump overload protection | |||
Chiller water shortage protection | |||
Water outlet temp. protection | |||
Compressor discharge temp. protection | |||
Compressor low pressure protection | |||
Compressor high pressure protection | |||
Sensor malfunction protection | |||
Compressor current input protection | |||
Fin temp. (Ambient temp.) protection | |||
Anti-frozen protection | |||
Sound level (semi-anechoic) | dB(A) | 62 | |
Operation water temp. | Cooling | °C | 7~25 |
Heating | °C | 30~55 | |
Ambient temperature | Cooling | °C | 10~48 |
Heating | °C | -10~21 | |
Remarks: | Specifications are based on the following conditions: | ||
Cooling: Chilled water inlet/outlet: 12°C / 7°C and outdoor ambient of 35°C DB | |||
Heating: Warm water inlet/outlet: 40°C / 45°C and outdoor ambient temp. 7°C DB/6°CWB | |||
Water side fouling factor: 0.086m 2°C/kW. |